Bell Flow Systems was recently asked to provide a meter suitable for accurately measuring and recording the flow of sea water being pumped across a beach at Hinkley Point.
To provide evidence of a sufficient pumped water supply, Bell Flow Systems was required to provide a suitable flow sensor to meet the demands of the application. The flow meter must be compatible with sea water and designed to cope with the challenging weather conditions found at this beach-side installation location. It must also be internally powered and capable of accurately logging the volume of water pumped. The ModMAG M5000 from Badger Meter was deemed to be the ideal solution.
The M5000 electromagnetic flow meter is battery powered, giving up to 20 years’ battery life, making it suitable for applications where power is not available. The robust amplifier has IP67 or optional IP68 ingress protection, making it suitable for harsh operating environments, and the meter itself measures with an accuracy of better than ±0.4%. The M5000 also benefits from an integral data logger, able to record and store the volume measured at programmable time intervals, which can be downloaded to PC software via the IrDA or RS232 ModBus communication ports.
Electromagnetic measuring technology is maintenance-free and operates without mechanical moving parts, prolonging the life of the meter and allowing it to be used with fluids that may contain solids, including sand and organic matter. The available options of meter liner and electrode materials make it an ideal choice for various corrosive and aggressive fluids, including seawater.