Digital X-ray in aerospace
30/08/2018
The aerospace industry demands the highest quality requirements for its products and uses non-destructive testing (NDT) for quality assurance. X-ray examination in particular plays a big role in this process. Today, digital radiography (DR) using digital detectors is being used more extensively than ever. In the past, classic radiography with X-ray film was used. The growing aerospace market needs fast, process-reliable testing. Many companies are switching to digital X-ray imaging as it requires shorter exposure times, eliminates harmful chemistry, simplifies evaluation and increases automation.Digital systems, however, require a constant and careful performance evaluation. This article introduces the main performance metrics and explains the underlying procedures. The performance values of a DR system are described by the following parameters:
- Spatial resolution (SRb): Resolution is one of the most important values for the performance evaluation of an X-ray system. The read-out electronics of the digital detectors (digital detector array (DDA)), matrix detector or flat-panel detector) determines the pixel size. Modern detectors have pixel sizes of 25-200 μm. The thickness and type of the so-called scintillators (X-ray excitable light-emitting layer on the read-out electronics) also decisively determine the resolution of flat-panel detectors. For thicker scintillators, there is more scattering within the luminescent layer, so in the worst case, for example, a 100 μm pixel-size detector may have a higher resolution than a 25 μm detector with a thick scintillator layer. The resolution is measured using a double-wire image quality indicator (IQI) and a test specimen with small wire pairs, the indentation of which is measured using a line profile. The first wire pair is searched for the where the dip between two wires is less than 20% (see image). The associated resolution can be read from a table.
- Contrast noise ratio (CNR): The contrast in the X-ray image can be determined through a single-wire IQI or hole-type IQI. In aerospace environments, hole test specimens to ASTM E1742/E1025 have prevailed. These specimens have a defined thickness and three holes where the diameter of holes corresponds to the single (1T), double (2T) and quadruple (4T) specimen thickness. Depending on the thickness of the irradiated component, the corresponding specimen is selected. In this example, 4T is selected and the mean grey value of the 4T hole is subtracted from the mean grey value on the specimen and divided by the standard deviation. The resulting value must be at least 2.5 to obtain a sufficiently contrasting image. Additionally, the contrast sensitivity (CS) can be calculated from this value.
- Signal-to-noise ratio (SNR): The signal-to-noise ratio describes the distance of the interference signal to the useful signal. The SNR is calculated from the mean grey value divided by the standard deviation in a homogeneous defined range. This value provides a factor for the achieved resolution of the normalised SNR ratio. Higher SNR values allow greater visibility of the errors and the images are visibly smoother. The way to improve SNR is to increase image integration.
After selecting the right X-ray tube detector combination for the application, it is essential to the aviation industry that the performance levels achieved at the beginning continue to be achieved permanently. This must be checked daily or even before each shift. For this reason, it is worked with so-called test phantoms. There are several types of phantoms:
- Duplex plate phantom according to ASTM E2737: This is a two-stage phantom; one plate corresponds to the thinnest thickness and the other plate corresponds to the thickest thickness to be tested. Placed on it are a double-wire bar and the two matching hole test pieces according to ASTM. The test parameters (kV/mA, focal spot size, pre-filtering, geometric magnification, detector mode, number of image integrations and exposure time) should be those of the later test. This phantom can be made individually according to the specific needs (size, thickness and material).
- Five-groove wedge according to ASTM E2737: This is a standardised specimen. There are two versions: heavy metal or light metal. Using the milled grooves, it is possible to determine the different thicknesses, the resolution and the contrast sensitivity.
- TAM phantom: This is a specially made phantom that covers the testing of titanium and Inconel parts up to 0.25 inches. At levels of 0.05-0.25 inches, the respective test specimens are in accordance with TAM ASTM E1742. The resolution is determined by two double wire webs.
By using CNC-controlled equipment, such as XRH222, XRH111 or XRHGantry from VisiConsult, these daily image quality tests can be completely automated. The Xplus Image Quality Evaluation Toolbox automates repetitive checks. Values such as CNR, SNR, SR, signal level (SL) and CS can be generated with one click and saved as a report.

The storage of digital images is based on a standard that was originally developed for medicine. With DICOM (or for the industry DICONDE) images, not only the uncompressed X-ray image but also process data are saved, which can be displayed again with a DICOM/DICONDE-compatible image viewer.
www.visiconsult.de